RUFTEElectric

Panel meter model selection guide

All panel meter series on this site in one place. Start from the panel opening you have, then check the measured quantity and input. “Ask us” marks values not printed in our catalogue — we confirm them with your quote.

Analog Meter Relays

Analog Meter Relays overview
ModelMeasuresAC / DCFront frame (mm)Panel cutout (mm)AccuracyExternal CT / PT / shuntAlarm relay
CH120H / CH120HLCurrent, voltageAC & DC120 × 100Ask usAC ±2.5%, DC ±1.5% FSCT x/1A & x/5A · PT · shunt 50/60/75 mVHigh / high+low, 3 A
CH100H / CH100HLCurrent, voltageAC & DC100 × 80See drawingAC ±2.5%, DC ±1.5% FSCT x/1A & x/5A · PT · shunt 50/60/75 mVHigh / high+low, 3 A
CH80HCurrent, voltageAC & DC80 × 80Ask usAC ±2.5%, DC ±1.5% FSCT x/1A & x/5A · PT · shunt 50/60/75 mVHigh limit, 3 A

Analog Ammeters & Voltmeters

Analog Ammeters & Voltmeters overview
ModelMeasuresAC / DCFront frame (mm)Panel cutout (mm)AccuracyExternal CT / PT / shuntAlarm relay
RS670Current, voltageAC & DC69 × 58Ø48Class 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
RJ670 / RJ80Current, voltageAC & DC (moving coil); AC A (moving iron)69 × 58 / 80 × 80Ø48 / Ask usClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
RPM670Current, voltage; r/min dial shownAC & DC70 × 60Ø52Class 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
59C23 / 44C17 / 69C17Current, voltageAC & DC129×69 / 108×60 / 87×47122×66 / 102×58 / 82×45Up to class 0.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
44C2/44L1, 69C/L9Current, voltageAC & DC100 × 80 / 80 × 64See drawingClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
85C/L1, 85C/L12, 59C2/59L1, 91C4Current, voltageAC & DCAsk usAsk usClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
RJ180-EL (EL backlit)Voltage, DC currentAC V & DC100 × 80 (as 44C2)See 44C2 drawingClass 1.5 or 2.5PT X/100–120V · shunt 50/60/75 mV—
63C/L7 (luminous dial)Ask usAsk usAsk usAsk usClass 1.5 or 2.5Ask us—
99C2 / 69C1 (slotted)DC current incl. 4–20 mA, DC voltageDC45 × 15.5 / 62 × 20Ask usAsk us——
TX70 / TW80DC µA / mA, DC voltageDC70 × 70 / 80 × 66.564 × 39 / 80 × 39Ask us——

Square Panel Meters

Square Panel Meters overview
ModelMeasuresAC / DCFront frame (mm)Panel cutout (mm)AccuracyExternal CT / PT / shuntAlarm relay
81L16 / 89L2 / 6L2 / 42L6Current, voltageAC48 / 72 / 80 / 120 squareSee drawingClass 1.5Ask us—
SQ48 / SQ72 / SQ96Current (1×–3× overload), voltageAC (moving iron)48 / 72 / 96 square45 / 68 / 91 squareClass 1.5 or 2.5CT x/5A · PT X/100–120V—
RSP-48A / 72A / 96ACurrent (1× or 2× overload)ACAsk usAsk usClass 1.5 or 2.5CT X/5A—
RSP-48V / 72V / 96VVoltage 0–10 … 0–600 VACAsk usAsk usClass 1.5PT X/100V—

Frequency, Power & Power Factor Meters

Frequency, Power & Power Factor Meters overview
ModelMeasuresAC / DCFront frame (mm)Panel cutout (mm)AccuracyExternal CT / PT / shuntAlarm relay
RS670 / RJ670 frequencyFrequency 45–65 HzAC 110/220/380/400 V69 × 58Ø48Ask us——
RSP-72C / 96CPower factorACAsk usAsk usClass 2.5CT X/5A—
RSP-W72(3b) / W96(3b)Active power, 3-phase 3-wireACAsk usAsk usClass 1.5CT X/5A · PT—
RSP-S72-D / S96-D (-DR)Synchronization (digital)ACAsk usAsk us15° / 3°PT X/100V, X/110V—
RSP-NI72A/D / NI96A/DNetwork insulationAC & DCAsk usAsk usClass 1.5 (AC) / 5 (DC)——

240° Wide-Angle Meters

240° Wide-Angle Meters overview
ModelMeasuresAC / DCFront frame (mm)Panel cutout (mm)AccuracyExternal CT / PT / shuntAlarm relay
45C/L8 (240°)Current, voltageAC & DC110 × 110Ask usClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
63C/L2 (240°)Current, voltageAC & DC80 × 80Ask usClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—
84C/L2 (240°)Current, voltageAC & DC60 × 60Ask usClass 1.5 or 2.5CT x/5A · PT X/100–120V · shunt 50/60/75 mV—

Above 10 A?

Use a dial for an external CT (x/5A; x/1A on CH meter relays) for AC, or a 50/60/75 mV shunt for DC — up to 3000 A.

Above 600 V?

Voltmeters read kV through an external PT with X/100V, X/110V or X/120V secondary.

Need an alarm output?

Only the CH series has set needles and a relay. Meter relays.

Request a quote

Not sure which model fits?

Send the panel cutout, the measured quantity and a photo of the meter you have now. We reply with the matching model and dial.

Request a QuoteWhatsApp