44C2 — 4–20 mA input, Hz scale
Analog Ammeters & Voltmeters
National-Standard Rectangular Ammeters & Voltmeters (44C2, 69C9, 85C, 59C2, 91C4)
The national-standard series of rectangular current and voltage meters with a moving-coil movement. Linear, even scales, strong resistance to electromagnetic interference and very wide application.
Specifications
| Movement | Moving coil, linear scale |
|---|---|
| Accuracy | Class 1.5 or 2.5 (AC/DC ammeters and voltmeters, p.2) |
| Operating temperature | −25 °C to +50 °C; extended-temperature versions on request |
Source: factory catalogue p.13–14. 44C2, 44L1 named on UDEM attestation M.2024.206.C99480.
Ranges
Measuring ranges — 44C2/44L1, 69C/L9, 85C/L1, 85C/L12, 59C2/59L1, 91C4
| Measurement | Unit / connection | Standard ranges |
|---|---|---|
| AC current | mA | 200mA, 500mA, 600mA, 800mA |
| A | 1A, 5A, 10A | |
| With external CT x/5A | 10/5A, 15/5A, 20/5A, 30/5A, 40/5A, 50/5A, 60/5A, 75/5A, 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 800/5A, 1000/5A, 1200/5A, 1500/5A, 2000/5A, 2500/5A | |
| AC voltage | V | 5V, 10V, 25V, 40V, 60V, 100V, 150V, 250V, 300V, 450V, 500V, 600V |
| kV | With an external PT: X/100V, X/110V, X/120V | |
| DC current | µA | 50µA, 100µA, 200µA, 500µA, 800µA |
| mA | 1mA, 10mA, 500mA, 800mA | |
| A | 1A, 1.5A, 2A, 3A, 4A, 5A, 10A | |
| External shunt 50 / 60 / 75 mV | 10A, 15A, 20A, 30A, 40A, 50A, 60A, 100A, 150A, 200A, 250A, 300A, 400A, 500A, 600A, 800A, 1000A, 1500A, 2000A, 2500A, 3000A | |
| DC voltage | V | 0.5V, 1V, 5V, 10V, 15V, 25V, 50V, 100V, 250V, 500V, 600V |
Source: factory catalogue p.13–14. Other ranges and dual scales — ask us.
Drawings
Dimensions & drawings
| Model | A1 | A2 | B | C | F | L | D | H1 | H2 | H3 | h | d |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 44L1 / 44C2 | 100 | 80 | 68.5 | 21.7 | 7.5 | 46.6 | Ø59 | 14.4 | 12 | 9.6 | 1.6 | M4 |
| 69C/L9 | 80 | 64 | 64 | 17.8 | 1 | 46 | Ø60 | 11.5 | 8 | 11.5 | 4 | M3 |

Ask us
- Dimensions for the 59, 85 and 91 series (drawn on p.13 but not in the dimension table)
- Samples and lead time — confirmed with each quote
- Custom scale, dial text or pointer — see custom dials