Analog Meter Relays — CH Series High/Low Alarm Meters
An analog meter relay is a pointer panel meter with a built-in output relay. The black pointer shows the live value; the red and green set needles mark the high and low limits. When the pointer passes a limit, the internal relay switches and controls the external circuit. Our CH series is used on multi-station cold heading machines and automatic testing equipment.

3 series in this range
Specifications
Compare analog meter relays
Values from our factory catalogue (p.3–5). “Ask us” = not in the catalogue yet — we confirm it with your quote.
| Model | Measures | AC / DC | Front frame (mm) | Panel cutout (mm) | Accuracy | External CT / PT / shunt | Alarm relay |
|---|---|---|---|---|---|---|---|
| CH120H / CH120HL | Current, voltage | AC & DC | 120 × 100 | Ask us | AC ±2.5%, DC ±1.5% FS | CT x/1A & x/5A · PT · shunt 50/60/75 mV | High / high+low, 3 A |
| CH100H / CH100HL | Current, voltage | AC & DC | 100 × 80 | See drawing | AC ±2.5%, DC ±1.5% FS | CT x/1A & x/5A · PT · shunt 50/60/75 mV | High / high+low, 3 A |
| CH80H | Current, voltage | AC & DC | 80 × 80 | Ask us | AC ±2.5%, DC ±1.5% FS | CT x/1A & x/5A · PT · shunt 50/60/75 mV | High limit, 3 A |
Buying information
Ordering analog meter relays
- To quote, we need
- Model (CH120H/HL, CH100H/HL or CH80H), AC or DC, current or voltage range — or the CT / shunt ratio — supply voltage, and quantity.
- Mixed models and ranges
- List every model and range in one inquiry and we quote them together.
- Minimum order, samples, lead time
- MOQ 50 pcs per model; smaller quantities possible at a surcharge.
- Samples and lead time: Ask us — confirmed in writing with each quote.
- Dial and scale options
- Any range in the table, CT x/1A or x/5A dials, PT and 50/60/75 mV shunt dials. Custom dials.
Manufacturing evidence
Made and documented in Ningbo
- Rectified moving-coil movement with a high-damping magnet (p.3).
- Relay rated 3 A per contact set at AC 110/220 V; mechanical life 200,000 operations (p.3).
- Switching differential within 1% of the indication; ON/OFF action error within 0.5% of full scale (p.3).
- CH80H, CH100H, CH100HL, CH120H and CH120HL are named on our UDEM LVD/EMC Attestation of Conformity No. M.2024.206.C99480.
Selection tips
Choosing the right model
- High limit only, or high and low?
- CH80H has one red needle for an upper limit. The CH100HL and CH120HL carry a red and a green needle for a high/low window (low 0–95%, high 5–100% of scale, at least 2° apart).
- Which size?
- Front frames are 120×100 mm (CH120), 100×80 mm (CH100) and 80×80 mm (CH80H). Match the existing panel opening — send its dimensions if you replace another meter.
- Direct or through a CT / shunt?
- Up to 10 A AC or DC can be measured directly; above that use an external CT (x/1A or x/5A, up to 3000 A) or a 50/60/75 mV DC shunt (up to 3000 A).
Request a quote
Request a Meter Relay Quote
Model (CH120H/HL, CH100H/HL or CH80H), AC or DC, current or voltage range — or the CT / shunt ratio — supply voltage, and quantity.
FAQ
Frequently Asked Questions
How does an analog meter relay work?
The black pointer shows the real-time value. The red and green needles are set by hand to the limits. When the pointer goes above the high limit or below the low limit, the internal relay switches at once and controls the external circuit.
Why use a meter relay instead of a digital controller?
Limits are set directly on the dial, the relay switching is reliable, and the pointer shows the dynamic trend of the value at a glance.
What supply voltage do the CH meter relays need?
The datasheet gives AC 108–132 V or AC 210–230 V, 50–60 Hz. DC 24 V and DC 12 V are also listed in the model table — tell us which you need and we confirm it with the quote.
Where are CH meter relays used?
Mainly on multi-station cold heading machines and automatic testing equipment, where a current or voltage must stay inside a window.
Where they are made