240° Wide-Angle Ammeters & Voltmeters
Wide-angle meters spread the scale over 240°, so the reading is longer and easier to see than on a 90° meter of the same size. Rectified AC and DC moving-coil design with a linear scale, in three square sizes.

3 series in this range
Specifications
Compare 240° wide-angle meters
Values from our factory catalogue (p.20). “Ask us” = not in the catalogue yet — we confirm it with your quote.
| Model | Measures | AC / DC | Front frame (mm) | Panel cutout (mm) | Accuracy | External CT / PT / shunt | Alarm relay |
|---|---|---|---|---|---|---|---|
| 45C/L8 (240°) | Current, voltage | AC & DC | 110 × 110 | Ask us | Class 1.5 or 2.5 | CT x/5A · PT X/100–120V · shunt 50/60/75 mV | — |
| 63C/L2 (240°) | Current, voltage | AC & DC | 80 × 80 | Ask us | Class 1.5 or 2.5 | CT x/5A · PT X/100–120V · shunt 50/60/75 mV | — |
| 84C/L2 (240°) | Current, voltage | AC & DC | 60 × 60 | Ask us | Class 1.5 or 2.5 | CT x/5A · PT X/100–120V · shunt 50/60/75 mV | — |
Buying information
Ordering 240° wide-angle meters
- To quote, we need
- Size (110, 80 or 60 mm), AC or DC, range or CT / shunt ratio, and quantity.
- Mixed models and ranges
- List every model and range in one inquiry and we quote them together.
- Minimum order, samples, lead time
- MOQ 50 pcs per model; smaller quantities possible at a surcharge.
- Samples and lead time: Ask us — confirmed in writing with each quote.
- Dial and scale options
- Ranges from the table, CT x/5A, PT and 50/60/75 mV shunt dials. Custom dials.
Manufacturing evidence
Made and documented in Ningbo
- Analog meters made to Chinese national standard GB/T 7676-1998 (p.2).
- Every meter is anti-static treated (p.2).
- 45L8, 45C8, 63L2 and 63C2 are named on our UDEM LVD/EMC Attestation of Conformity No. M.2024.206.C99480.
Selection tips
Choosing the right model
- Why 240°?
- The pointer sweeps 240° instead of 90°, so the scale arc is much longer for the same bezel size.
- Which size?
- 45C/L8 is 110×110 mm, 63C/L2 is 80×80 mm and 84C/L2 is 60×60 mm (front).
- AC or DC?
- All three are rectified moving-coil meters with linear scales, for AC and DC current or voltage.
Request a quote
Request a Wide-Angle Meter Quote
Size (110, 80 or 60 mm), AC or DC, range or CT / shunt ratio, and quantity.
FAQ
Frequently Asked Questions
What is a wide-angle meter?
An analog meter whose pointer sweeps 240° instead of the usual 90°, giving a longer scale in the same panel space.
Which sizes are available?
110×110 mm (45C/L8), 80×80 mm (63C/L2) and 60×60 mm (84C/L2).
Can a wide-angle meter work with a CT or shunt?
Yes: CT x/5A (10/5A–2500/5A), PT X/100V–X/120V and 50/60/75 mV shunts up to 3000 A.
Where they are made