59C23 — 100 µA special
Analog Ammeters & Voltmeters
59C23, 44C17 & 69C17 High-Accuracy Frame Meters (up to Class 0.5)
Embedded (frame) installation with an internal-magnet moving-coil movement, mainly used in high-end measuring instruments and equipment. The flattened scale gives a wide field of view and high resolution. A high-temperature version of the same meter works from −25 °C to +80 °C for special applications.
Specifications
| Accuracy | Up to class 0.5 |
|---|---|
| Movement | Moving coil, internal magnet |
| Mounting | Embedded / frame installation |
| High-temperature version | −25 °C to +80 °C (same meter, p.11) |
Source: factory catalogue p.11–12. 59C23, 44C17, 69C17 named on UDEM attestation M.2024.206.C99480.
Ranges
Measuring ranges — 59C23 / 44C17 / 69C17
| Measurement | Unit / connection | Standard ranges |
|---|---|---|
| AC current | mA | 500mA, 600mA, 800mA |
| A | 1A, 5A, 10A | |
| With external CT x/5A | 10/5A, 15/5A, 20/5A, 30/5A, 40/5A, 50/5A, 60/5A, 75/5A, 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 800/5A, 1000/5A, 1200/5A, 1500/5A, 2000/5A, 2500/5A | |
| AC voltage | V | 10V, 25V, 40V, 60V, 100V, 150V, 250V, 300V, 450V, 500V, 600V |
| kV | With an external PT: X/100V, X/110V, X/120V | |
| DC current | µA | 50µA, 100µA, 200µA, 500µA, 800µA |
| mA | 1mA, 10mA, 50mA, 100mA, 200mA, 500mA, 800mA | |
| A | 1A, 1.5A, 2A, 3A, 4A, 5A, 10A | |
| External shunt 50 / 60 / 75 mV | 10A, 15A, 20A, 30A, 40A, 50A, 60A, 100A, 150A, 200A, 250A, 300A, 400A, 500A, 600A, 800A, 1000A, 1500A, 2000A, 2500A, 3000A | |
| DC voltage | V | 0.5V, 1V, 5V, 10V, 15V, 25V, 50V, 100V, 250V, 500V, 600V |
Source: factory catalogue p.11–12. Other ranges and dual scales — ask us.
Drawings
Dimensions & drawings
| Model | Front frame | Panel cutout |
|---|---|---|
| 59C23 | 129 × 69 | 122 × 66 |
| 44C17 | 108 × 60 | 102 × 58 |
| 69C17 | 87 × 47 | 82 × 45 |

Applications
- Bearing testers
- High-end teaching instruments
Ask us
- Full dimension set for 69C17 (one value unclear in the catalogue)
- Samples and lead time — confirmed with each quote
- Custom scale, dial text or pointer — see custom dials
Request a quote
Quote for 59C23 / 44C17 / 69C17
Tell us AC or DC, the range or CT / shunt ratio, any dial changes and the quantity. Attach a photo or drawing of the meter you replace if you have one.
Need to compare first? Model selection guide · Request the attestation